Auto Generator Alternator Starter

|
|
Manufacturer: |
Sun Electric
|
|
|
|
|
|
|
|
|
|
Volts: 220/440
HZ: 60
Phase: 3
Speed range: 800-11,000RPM
HP: 22-30
Purpose
The Test Stand is designed to functionally test twelve (12) and twenty-four (24) volt Generators, Alternators and their associated regulating and rectifying equipment. The test stand has provision for free-running and lock-torque testing of twelve (12) and twenty-four (24) volts starter.
Leading Particulars
Dual head drive
Load bank 0-500 AMPS, DC
Working lamp Operates on 115 volts AC on-off switch.
Operating Limitation
Temperature range -25º F to +115º F
Relative Humidity 97%
Motor and Drive Unit
Motor Continuous duty: 22½ HP, 220/440V, 60 HZ, 3 Phase.
Intermittent duty: 35 HP for 1 hour, 97.0/48.5 Amperes, 220/440V, 60 HZ
In-rush current at 440V is 190 amperes, in-rush current at 220V is 380 amperes
Drive - Two shaft Low speed 800 to 4800 RPM (rear shaft), high speed 1830 to 11,000 RPM (front shaft)
Air intake Top left side provides cooling air for Load Bank and Cooling Chambers
Exhaust Manifold Top left side removes heats from Load Bank and Cooling Chamber
|
|
Approx.
Dimensions: |
65" H x 44" D x 66.75" L
|
|
|
Approx.
Weight: |
2780 lbs.
|
|
|